C4-80 POST PORCELAIN ISOLATORS
Video Drawing Parameter table Indicator C4-80 II UHL C4-80 I T C4-80 I UHL C4-80 I T Rated voltage kV 10 10 10 10 Minimum bending strength kN 4 4 4 4 Construction height mm 215 215 190 190 Creepage distance mm 30 30 20 20 Weight kg 2.6 2.6 2.1 2.1 Insulating part diameter D mm 125 125 125 125 Upper flange, D 1 mm 36 36 36 36 Lower flange, D 2 mm 70 70 70 70 Test voltage of (full) lightning impulse kV 80 80 80 80 Марка изолятора: С4-80 II Номинальное напряжение: ... -
Russia Type C4-80 II 10kv Porcelain Post Insulator
Russia type 10KV C4-80 II porcelain post insulator
Lightning impulse withstand voltage 10 kV
Creepage distance 320 mm
Failing load, bending 4 kN
Metal accessories : Nodular Cast Iron, or Aluminum -
C4-125 Ceramic Solid Core Station Post isolators
24kv post porcelain insulator is made of post insulator,called C4-125 post insulator,we applicate it in the 24kv power line switch gear. The body is the post insulator,the top and bottom fix with fitting. -
33kV high voltage post porcelain insulator 57-2 ANSI class standard
High voltage line rod insulator is used as insulation and supporting conductor in high voltage transmission and distribution line. The product is a non breakdown structure and has the advantages of high mechanical strength, strong insulation performance and good pollution resistance. The insulator has the advantages of safe and reliable operation, simple maintenance, long service life and low line cost. -
-
-
35kV solid core post cylindrical insulator porcelain insulator
Outdoor Solid-Core station Post Insulators -
-
220-252kV Solid-Core Post Insulators
ZS-Solid Core Post Insulators;ZSX-Catanary Post Insulators;C-Operation Post Insulators;W-Anti-pollution Type;Numerator after frist"-"-Rated Voltage;Denominator-Catilever Failing Load;N-Torsion Failing Load;L-Bottom and Top Fittings are all with Screw Hole;Data after second"-"-Class of Pollution Level. -
12-72.5kV Solid-Core Post Insulators
ZS-Solid Core Post Insulators;ZSX-Catanary Post Insulators;C-Operation Post Insulators;W-Anti-pollution Type;Numerator after frist"-"-Rated Voltage;Denominator-Catilever Failing Load;N-Torsion Failing Load;L-Bottom and Top Fittings are all with Screw Hole;Data after second"-"-Class of Pollution Level. -
126-145kV Anti-pollution Type Solid-Core Post Insulators
ZS-Solid Core Post Insulators;ZSX-Catanary Post Insulators;C-Operation Post Insulators;W-Anti-pollution Type;Numerator after frist"-"-Rated Voltage;Denominator-Catilever Failing Load;N-Torsion Failing Load;L-Bottom and Top Fittings are all with Screw Hole;Data after second"-"-Class of Pollution Level. -
12kV-252kV Outdoor Solid-Core Post Insulators/20kV 35kV 72.5kV 126kV 220kV 145kV 550kV station post insulator
ZS-Solid Core Post Insulators;ZSX-Catanary Post Insulators;C-Operation Post Insulators;W-Anti-pollution Type;Numerator after frist"-"-Rated Voltage;Denominator-Catilever Failing Load;N-Torsion Failing Load;L-Bottom and Top Fittings are all with Screw Hole;Data after second"-"-Class of Pollution Level.
20kV 35kV 72.5kV 126kV 220kV 145kV 550kV station post insulator
12.5kV-72.5kV Outdoor Solid-Core Post Insulators
126kV-145kV Outdoor Solid-Core Post Insulators
220kV-252kV Outdoor Solid-Core Post Insulators