54-2 Porcelain Insulator Stay Insulator Guy Insulator
Parameter Stay insulators ANSI Class 54-2
Creepage distance 48mm
Mechanical Values Cantilever strength 55kn
Tension insulator is used for power frequency AC or DC overhead power lines, pole stay wire or tension conductor and insulation. The ambient temperature of the installation site is - 40 ℃ ~ + 40 ℃, and the altitude is no more than 1000m. -
Strain Type Stay Porcelain Insulator for Overhead Transmission Line
Type: Porcelain Insulator
Material: Porcelain
Application: High Voltage
Tensile Strength: 44KN~89KN
-
ANSI54-2 high tension stay porcelain insulator
Parameter Stay insulators ANSI Class 54-2
Creepage distance 48mm
Mechanical Values Cantilever strength 55kn
Tension insulator is used for power frequency AC or DC overhead power lines, pole stay wire or tension conductor and insulation. The ambient temperature of the installation site is - 40 ℃ ~ + 40 ℃, and the altitude is no more than 1000m. -
ANSI 54-2 Porcelain Guy Strain Stay Insulator
The Stay porcelain insulators transmission line insulators is used for high voltage. -
ANSI 54-3 brown ceramic insulator Porcelain Stay Guy Strain isolators
57kn Factory Price 54-3 Stay Insulator
Tension insulator is used for power frequency AC or DC overhead power lines, pole stay wire or tension conductor and insulation. The ambient temperature of the installation site is - 40 ℃ ~ + 40 ℃, and the altitude is no more than 1000m. -
HT ANSI 54-3 stay porcelain insulator guy Ceramic isolators
89KN stay porcelain insulator for low voltage porcelain IEC60383
Tension insulator is used for power frequency AC or DC overhead power lines, pole stay wire or tension conductor and insulation. The ambient temperature of the installation site is - 40 ℃ ~ + 40 ℃, and the altitude is no more than 1000m.
Tension insulator is used for power frequency AC or DC overhead power lines, pole stay wire or tension conductor and insulation. The ambient temperature of the installation site is - 40 ℃ ~ + 40 ℃, and the altitude is no more than 1000m. -
ANSI 54-1 Best price 44KN porcelain Strain Insulator
ANSI 54-1 Low Voltage 45kn Stay isolators
Tension insulator is used for power frequency AC or DC overhead power lines, pole stay wire or tension conductor and insulation. The ambient temperature of the installation site is - 40 ℃ ~ + 40 ℃, and the altitude is no more than 1000m. -
ANSI 54-4 HT guy ceramic insulator
11KV stay porcelain insulator for electrical transmission line
Tension insulator is used for power frequency AC or DC overhead power lines, pole stay wire or tension conductor and insulation. The ambient temperature of the installation site is - 40 ℃ ~ + 40 ℃, and the altitude is no more than 1000m. -
222KN Guy Wire Porcelain Insulator GY4 Ceramic isolators
Professional Manufacturer Focused on Quality manufacture Guy Wire Insulator
AS standard GY3 / GY4 Porcelain insulator is used with stay wire to pull them and fix the stay wire and stay assembly together onto the ground.
Tension insulator is used for power frequency AC or DC overhead power lines, pole stay wire or tension conductor and insulation. The ambient temperature of the installation site is - 40 ℃ ~ + 40 ℃, and the altitude is no more than 1000m. -
GY-3 high voltage strain guy Ceramic isolators
ANSI Class Gy3 china Factory Porcelain Ceramic Stay isolators
Tension insulator is used for power frequency AC or DC overhead power lines, pole stay wire or tension conductor and insulation. The ambient temperature of the installation site is - 40 ℃ ~ + 40 ℃, and the altitude is no more than 1000m. -
-
Factory Price 54-1 Low Voltage 45kn Stay isolators
Stay insulators ANSI Class 54-1 54-2 54-3 54-4 Dimensions Diameter mm Height mm 89 108 140 172 Creepage distance mm 41 48 57 76 Mechanical Values Cantilever strength kn 45 55 91 91 Electrical Values Low frequency dry flashover voltage kv 25 30 35 40 Low frequency wet flashover voltage kv 12 15 18 23 Packing and Shipping Data Net weight,approximate kg 0.50 0.65 1.20 1.85