— Jiangxi Johnson Electric Co., Ltd. —
English
Home
Products
Russian Type Products
Porcelain Insulators
Suspension Porcelain Insulators
Disc Porcelain Insulator
Long Rod insulators
Fog type suspension porcelain insulators
Pin Insulator
High Voltage Pin Insulator
Low Voltage Pin Insulator
Pin insulator for telephone lines
Post Insulators
Line Post Insulator
Station Post Insulator
disconnector switch isolator
Pin Post Insulators
Transformer Bushing
Fuse Cutout Insulator
Shackle Insulators
Spool Insulators
Stay Insulators
Glass Insulators
Composite Insulators
Power Fittings
Aluminum strain clamp(Bolt Type)
News
FAQs
About Us
Factory Tour
Customer Photos
Exhibition
Hot-Sale Product
Certificate
Contact Us
Home
Featured
Featured
Renewable Design for High Tension Ceramic Insulator - NLL Aluminum strain clamp(Bolt Type) – Johnson
NLD Series Aluminium Alloy Tension Clamp Basic Data Type Diameter of stranded wire Dimensions (mm) U bolt Rated Failure Load(KN) Cover used Weight M C L1 L2 Nos Dia.(mm) (kg) NLL-1 5.0-10.0 16 19 140 120 2 10 40 JNL-1 1.0 NLL-2 10.1-14.0 16 24 176 187 2 12 40 JNL-2 1.6 NLL-3 14.1-18.0 16 18 310 160 3 12 70 JNL-3 1.9 NLL-4 18.1-23.0 16 30 298 284 3 12 90 JNL-4 4.1 NLL-5 23.1-29.0 22 36 446 342 5 12 120 JNL-5 7.0 Advantages of strain clamp: 1. Effectiv...
inquiry
detail
Discount wholesale 160kn Ceramic Insulator - NLD Aluminum strain clamp(Bolt Type) – Johnson
NLD Series Aluminium Alloy Tension Clamp Basic Data Type Diameter of stranded wire Dimensions ( mm ) U bolt U.T.S Weight L1 L2 R C M Nos Dia.(mm) (kn) (kg) NLD-1 5.0-10.0 150 120 6.5 18 16 2 12 20 1.24 NLD-2 10.1-14.0 205 130 8.0 18 16 3 12 40 1.90 NLD-3 14.1-18.0 310 160 11.0 22 18 4 16 70 4.24 NLD-4 18.1-23.0 410 220 12.5 25 18 4 16 90 6.53 NLD-4B 18.1-23.0 370 200 12.5 27 18 4 16 90 6.57 NLD bolt type aluminum alloy tension clamp is used for non load-bea...
inquiry
detail
PriceList for Stay Porcelain Insulator - NLD Aluminum strain clamp(Bolt Type) – Johnson
NLD Series Aluminium Alloy Tension Clamp Basic Data Type Diameter of stranded wire Dimensions ( mm ) U bolt U.T.S Weight L1 L2 R C M Nos Dia.(mm) (kn) (kg) NLD-1 5.0-10.0 150 120 6.5 18 16 2 12 20 1.24 NLD-2 10.1-14.0 205 130 8.0 18 16 3 12 40 1.90 NLD-3 14.1-18.0 310 160 11.0 22 18 4 16 70 4.24 NLD-4 18.1-23.0 410 220 12.5 25 18 4 16 90 6.53 NLD-4B 18.1-23.0 370 200 12.5 27 18 4 16 90 6.57 NLD bolt type aluminum alloy tension clamp is used for non load-bea...
inquiry
detail
factory Outlets for P-33-Y Pin Insulator - 11kn AS Standard P-11-A Pin Type Porcelain Insulator – Johnson
AS standard pin type insulator Class AS P-11-A Dimensions Main Dimensions H mm 107 h mm 40 D mm 140 d mm 76 R1 mm 16 R2 mm 13 Creepage Distance mm 180 Mechanical Values Cantilever Failing Load kN 11 Electrical Values Nominal Voltage kV 11 Minimum Flashover Voltage Power frequency Dry kV 60 Wet kV 32 50% Critical Impulse (peak) kV 95 Power-frequency Puncture Voltage kV 95 Packing and Shipping Data Weight kg 1.3
inquiry
detail
Excellent quality Ed-2b Shackle Insulator - NLL Aluminum strain clamp(Bolt Type) – Johnson
NLD Series Aluminium Alloy Tension Clamp Basic Data Type Diameter of stranded wire Dimensions (mm) U bolt Rated Failure Load(KN) Cover used Weight M C L1 L2 Nos Dia.(mm) (kg) NLL-1 5.0-10.0 16 19 140 120 2 10 40 JNL-1 1.0 NLL-2 10.1-14.0 16 24 176 187 2 12 40 JNL-2 1.6 NLL-3 14.1-18.0 16 18 310 160 3 12 70 JNL-3 1.9 NLL-4 18.1-23.0 16 30 298 284 3 12 90 JNL-4 4.1 NLL-5 23.1-29.0 22 36 446 342 5 12 120 JNL-5 7.0 Advantages of strain clamp: 1. Effectiv...
inquiry
detail
China Supplier 35kv Line Post Insulator - 24kv 13kn Pin Post Insulator for High Voltage – Johnson
24kv 13kn Pin Post Insulator for High Voltage Standdard applied IEC 60383 Spacing mm 385 Rate voltage kV 24 Creepage distance mm 600 Cantilever streength kN 13 Power frequency dry withstant voltage kV 75 Power frequency wet withstant voltage kV 55 Lightning impulse withstand voltage kV 125 Power frequency puncture voltage kV 160 Net Weight Each Approx kg 11.8
inquiry
detail
Cheapest Factory 0.4kv Strain Porcelain Insulator - NLD Aluminum strain clamp(Bolt Type) – Johnson
NLD Series Aluminium Alloy Tension Clamp Basic Data Type Diameter of stranded wire Dimensions ( mm ) U bolt U.T.S Weight L1 L2 R C M Nos Dia.(mm) (kn) (kg) NLD-1 5.0-10.0 150 120 6.5 18 16 2 12 20 1.24 NLD-2 10.1-14.0 205 130 8.0 18 16 3 12 40 1.90 NLD-3 14.1-18.0 310 160 11.0 22 18 4 16 70 4.24 NLD-4 18.1-23.0 410 220 12.5 25 18 4 16 90 6.53 NLD-4B 18.1-23.0 370 200 12.5 27 18 4 16 90 6.57 NLD bolt type aluminum alloy tension clamp is used for non load-bea...
inquiry
detail
Manufacturer of Anti-Pollution Type Porcelain Insulator - NLD Aluminum strain clamp(Bolt Type) – Johnson
NLD Series Aluminium Alloy Tension Clamp Basic Data Type Diameter of stranded wire Dimensions ( mm ) U bolt U.T.S Weight L1 L2 R C M Nos Dia.(mm) (kn) (kg) NLD-1 5.0-10.0 150 120 6.5 18 16 2 12 20 1.24 NLD-2 10.1-14.0 205 130 8.0 18 16 3 12 40 1.90 NLD-3 14.1-18.0 310 160 11.0 22 18 4 16 70 4.24 NLD-4 18.1-23.0 410 220 12.5 25 18 4 16 90 6.53 NLD-4B 18.1-23.0 370 200 12.5 27 18 4 16 90 6.57 NLD bolt type aluminum alloy tension clamp is used for non load-bea...
inquiry
detail
Best quality Transformer Bushing Porcelain Insulator - 36kv 30NF250 High Voltage Transformer Porcelain Bushing – Johnson
Product Definition The transformer bushing is the main insulation device outside the transformer box. The lead wires of the transformer windings must pass through the insulating bushing to insulate between the lead wires and between the lead wires and the transformer shell, and at the same time play the role of fixing the lead wires. Due to the different voltage levels, insulating bushings include pure porcelain bushings, oil-filled bushings and capacitor bushings. Pure porcelain bushings are...
inquiry
detail
factory low price 33kv Pin Ceramic Insulator - LV Power Line RM-2 Pin Type Telegraph Porcelain Ceramic Insulator – Johnson
Stay insulators Model NO. RM-2 Main dimension H mm 100 h mm 32 D mm 70 d mm 44 d1 mm 19 R1 mm 8.5 R2 mm 3.5 Mechanical Values Insulation resistance M 40000 Packing and Shipping Data Net weight,approximate kg 0.5 Product performance Mechanical properties: insulators are often subjected to the action of gravity and tension of the wire, wind force, ice weight, insulator dead weight, wire vibration, mechanical force of equipment operation, short-circuit electr...
inquiry
detail
Quality Inspection for High Voltage Transformer Bushing - 12kv 10NF250 High Voltage Transformer Porcelain Bushing – Johnson
Bushings are manufactured to DIN 42531,52432,42533 PART NUMBER DESCRIPTION Kv RATING I RATING TANK HOLESIZE BIL PF DRY PF WET CREEPAGE STEM CONNECT 10NF250 DIN 42531 10NF250 12 250 78 75 28 - 305 M12 10NF630 DIN 42532 10NF630 12 630 90 75 28 - 305 M20 10NF1000 DIN 42533 10NF1000 12 1000 110 75 28 - 295 M30 10NF2000 DIN 42533 10NF2000 12 2000 135 75 28 - 295 M42 10NF3150 DIN 42533 10NF3150 12 3150 135 75 28 - 295 M48
inquiry
detail
High reputation C4-125 Post Insulator - C4-125 4kn Station Post Porcelain Insulator – Johnson
inquiry
detail
<<
< Previous
320
321
322
323
324
325
326
Next >
>>
Page 323 / 349