English
Home
Products
Russian Type Products
Porcelain Insulators
Suspension Porcelain Insulators
Disc Porcelain Insulator
Long Rod insulators
Fog type suspension porcelain insulators
Pin Insulator
High Voltage Pin Insulator
Low Voltage Pin Insulator
Pin insulator for telephone lines
Post Insulators
Line Post Insulator
Station Post Insulator
disconnector switch isolator
Pin Post Insulators
Transformer Bushing
Fuse Cutout Insulator
Shackle Insulators
Spool Insulators
Stay Insulators
Glass Insulators
Composite Insulators
Power Fittings
Aluminum strain clamp(Bolt Type)
News
FAQs
About Us
Factory Tour
Customer Photos
Exhibition
Hot-Sale Product
Certificate
Contact Us
Home
Featured
Featured
Europe style for 55kv Post Insulator - 24kv 13kn Pin Post Insulator for High Voltage – Johnson
24kv 13kn Pin Post Insulator for High Voltage Standdard applied IEC 60383 Spacing mm 385 Rate voltage kV 24 Creepage distance mm 600 Cantilever streength kN 13 Power frequency dry withstant voltage kV 75 Power frequency wet withstant voltage kV 55 Lightning impulse withstand voltage kV 125 Power frequency puncture voltage kV 160 Net Weight Each Approx kg 11.8
inquiry
detail
professional factory for 11kv Post Porcelain Insulator - C4-125 4kn Station Post Porcelain Insulator – Johnson
inquiry
detail
High Quality Glass Insulator - High Voltage 40kn Disc Suspension Toughened Glass Insulator U40B White Transparent – Johnson
IEC designation U40B/110 Diameter D mm 178 Height H mm 110 Creepage distance L mm 185 Socket coupling mm 11 Mechanical failing load kn 40 Mechanical routine test kn 20 Wet power frequency withstand voltage kv 25 Dry lightning impulse withstand voltage kv 50 Impulse puncture voltage P.U 2.8 Power frequency puncture voltage kv 90 Radio influence voltage μv 50 Corona visual test kv 18/22 Power frequency electric arc voltage ka 0.12s/20kA Net weight per unit kg ...
inquiry
detail
OEM/ODM Factory U120bl Suspension Porcelain Insulator - 45KN 7sheds long rod insulator – Johnson
inquiry
detail
OEM/ODM China 30nf1000 Transformer Bushing - 24kv 20NF250 High Voltage Transformer Porcelain Bushing – Johnson
Bushings are manufactured to DIN 42531,52432,42533 PART NUMBER DESCRIPTION Kv RATING I RATING TANK HOLESIZE BIL PF DRY PF WET CREEPAGE STEM CONNECT 20NF250 DIN 42531 20NF250 24 250 78 125 50 - 450 M12 20NF630 DIN 42532 20NF630 24 630 90 125 50 - 440 M20 20NF1000 DIN 42533 20NF1000 24 1000 110 125 50 - 445 M30 20NF2000 DIN 42533 20NF2000 24 2000 135 125 50 - 445 M42 20NF3150 DIN 42533 20NF3150 24 3150 135 125 50 - 445 M48
inquiry
detail
Hot Sale for 33kv Pw-33-Y Pin Insulator - P-11-Y 11kv Pin type Porcelain Insulator for high voltage – Johnson
Pin type porcelain insulators type P-11-Y Dimensions Diameter mm 135 Height mm 140 Total creepage distance mm 254 Protected creepage distance mm 102 Recommended pin height mm 152 Mechanical Values Cantilever strength kn 11 Electrical Values Type application voltage kv 11 Power frequency dry flashover voltage kv 75 Power frequency wet flashover voltage kv 50 50% impulse flashover voltage,positive kv 115 50% impulse flashover voltage,negative kv 150 Powe...
inquiry
detail
Factory Outlets 52-9 Porcelain Insulator - NLL Aluminum strain clamp(Bolt Type) – Johnson
NLD Series Aluminium Alloy Tension Clamp Basic Data Type Diameter of stranded wire Dimensions (mm) U bolt Rated Failure Load(KN) Cover used Weight M C L1 L2 Nos Dia.(mm) (kg) NLL-1 5.0-10.0 16 19 140 120 2 10 40 JNL-1 1.0 NLL-2 10.1-14.0 16 24 176 187 2 12 40 JNL-2 1.6 NLL-3 14.1-18.0 16 18 310 160 3 12 70 JNL-3 1.9 NLL-4 18.1-23.0 16 30 298 284 3 12 90 JNL-4 4.1 NLL-5 23.1-29.0 22 36 446 342 5 12 120 JNL-5 7.0 Advantages of strain clamp: 1. Effectiv...
inquiry
detail
Factory directly 57-3 Post Insulator - P-70 Porcelain Post Insulator – Johnson
Product Definition Post insulator is a special insulation control which can play an important role in overhead transmission line. In the early years, pillar insulators were mostly used for telephone poles, which were gradually developed to hang a lot of suspension-like insulators at the end of the high-voltage wire connection tower to increase the creepage distance. They are usually made of silica gel or ceramic, and are called insulators. Insulator in overhead transmission lines with two b...
inquiry
detail
OEM Factory for U210b Suspension Porcelain Insulator - 160kn U160BL Disc Suspension Porcelain Insulator – Johnson
Ball and socket type suspension porcelain insulators( IEC Class ) Type XP2-160 IEC Class U160BL Coupling size 20 Dimensions Diameter(D) mm 280 Spacing(H) mm 170 Leakage distance mm 380 Mechanical Values Combined M&E strength kn 160 Impact strength N.m 10 Routine proof test load kn 80 Electrical Values power frequency dry withstand voltage kv 75 power frequency wet withstand voltage kv 42 Dry lightning impulse withstand voltage kv 110 Power frequenc...
inquiry
detail
Hot New Products Polymer Isolator - 24kv 70kn Rod Suspension Composite Insulator Polymer FXB-24-70 – Johnson
Rod Suspension Composite Insulator Polymer Type Rated voltage Rated Rated mechanical load Creepage distance Power frequency wet withstand voltage Dry lightning impulse withstand voltage (kV) (kN) (mm) (kV) (kV) FXB-24/70 24 70 760 95 200 Product Definition Composite insulator is a high voltage insulator made of organic silicone rubber composite material. The main products are bar type and cross arm type, which can be used as overhang and tensile bearing insulation on 35kV,...
inquiry
detail
Factory Promotional Dt 1/630 Transformer Bushing - 36kv 30NF250 High Voltage Transformer Porcelain Bushing – Johnson
Product Definition The transformer bushing is the main insulation device outside the transformer box. The lead wires of the transformer windings must pass through the insulating bushing to insulate between the lead wires and between the lead wires and the transformer shell, and at the same time play the role of fixing the lead wires. Due to the different voltage levels, insulating bushings include pure porcelain bushings, oil-filled bushings and capacitor bushings. Pure porcelain bushings are...
inquiry
detail
Competitive Price for 24kv Fuse Cutout Insulator - NLL Aluminum strain clamp(Bolt Type) – Johnson
NLD Series Aluminium Alloy Tension Clamp Basic Data Type Diameter of stranded wire Dimensions (mm) U bolt Rated Failure Load(KN) Cover used Weight M C L1 L2 Nos Dia.(mm) (kg) NLL-1 5.0-10.0 16 19 140 120 2 10 40 JNL-1 1.0 NLL-2 10.1-14.0 16 24 176 187 2 12 40 JNL-2 1.6 NLL-3 14.1-18.0 16 18 310 160 3 12 70 JNL-3 1.9 NLL-4 18.1-23.0 16 30 298 284 3 12 90 JNL-4 4.1 NLL-5 23.1-29.0 22 36 446 342 5 12 120 JNL-5 7.0 Advantages of strain clamp: 1. Effectiv...