Short Lead Time for High Tension Glass Insulator - High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B – Johnson

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We also offer product sourcing and flight consolidation services. We have our own factory and sourcing office. We can provide you with almost every type of product related to our product range for Fog Type Glass Insulator, U300b Disc Porcelain Insulator, U40b Ceramic Insulator, Our customers mainly distributed in the North America, Africa and Eastern Europe. we will source top quality goods using the really aggressive selling price.
Short Lead Time for High Tension Glass Insulator - High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B – Johnson Detail:

Product Definition

Glass insulators an insulator made of tempered glass. Its surface is in the state of compression prestress, such as crack and electrical breakdown, glass insulator will break into small pieces, commonly known as “self-explosion”. This feature eliminates the need for “zero value” detection of glass insulators during operation.
The glass insulator is the crystallization of the combination of glass and insulator. Because of the characteristics of glass compared with electric porcelain, glass insulators have better stability in electrical and mechanical characteristics, and their transparency makes it easy to check the damage during operation, so that the regular electrified preventive test for insulators is cancelled. The electrical strength of glass generally remains the same throughout its operation, and its aging process is much slower than that of porcelain. Therefore, glass insulators are mainly abandoned due to self-damage, which occurs within the first year of operation, whereas the defects of porcelain insulators begin to be discovered only after several years of operation.

rhetrh

This standard specifies the general technical requirements, selection principles, inspection rules, acceptance, packaging and transportation, installation and operational maintenance, and operational performance testing for ac overhead line insulators with nominal voltages above 1000V.

This standard is applicable to disk-type suspended porcelain and glass insulators (insulators for short) used in ac overhead power lines, power plants and substations with nominal voltage above 1000Y and frequency 50Hz. The altitude of the installation site must be lower than 1000m, and the ambient temperature must range from -40 ° c to +40 ° c. 2 Normative reference files

High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B (4)

IEC designation U160B/146 U160B/155 U160B/170
Diameter D mm 280 280 280
Height H mm 146 155 170
Creepage distance L mm 400 400 400
Socket coupling mm 20 20 20
Mechanical failing load kn 160 160 160
Mechanical routine test kn 80 80 80
Wet power frequency withstand voltage kv 45 45 45
Dry lightning impulse withstand voltage kv 110 110 110
Impulse puncture voltage P.U 2.8 2.8 2.8
Power frequency puncture voltage kv 130 130 130
Radio influence voltage μv 50 50 50
Corona visual test kv 18/22 18/22 18/22
Power frequency electric arc voltage ka 0.12s/20Ka 0.12s/20Ka 0.12s/20Ka
Net weight per unit kg 6.7 6.6 6.7

Product detail pictures:

Short Lead Time for High Tension Glass Insulator - High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B – Johnson detail pictures

Short Lead Time for High Tension Glass Insulator - High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B – Johnson detail pictures

Short Lead Time for High Tension Glass Insulator - High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B – Johnson detail pictures

Short Lead Time for High Tension Glass Insulator - High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B – Johnson detail pictures

Short Lead Time for High Tension Glass Insulator - High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B – Johnson detail pictures

Short Lead Time for High Tension Glass Insulator - High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B – Johnson detail pictures

Short Lead Time for High Tension Glass Insulator - High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B – Johnson detail pictures

Short Lead Time for High Tension Glass Insulator - High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B – Johnson detail pictures

Short Lead Time for High Tension Glass Insulator - High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B – Johnson detail pictures


Related Product Guide:

The consumer fulfillment is our primary goal. We uphold a consistent level of professionalism, top quality, credibility and service for Short Lead Time for High Tension Glass Insulator - High Voltage 160kn Disc Suspension Toughened Glass Insulator U160B – Johnson, The product will supply to all over the world, such as: Namibia, Grenada, Zurich, We are introduced as a one of the growing manufacture supplier and export of our products. We have a team of dedicated trained professional who take care the quality and timely supply. If you are looking for Good Quality at a good price and timely delivery. Do contact us.
  • This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
    5 Stars By David from United Arab Emirates - 2018.09.21 11:01
    The company's products very well, we have purchased and cooperated many times, fair price and assured quality, in short, this is a trustworthy company!
    5 Stars By Bertha from Denmark - 2017.09.28 18:29

    Related Products