To fulfill the customers' over-expected satisfaction , we have now our strong crew to provide our greatest general assistance which incorporates promoting, gross sales, planning, creation, top quality controlling, packing, warehousing and logistics for Post Insulator, 33kv Strain Ceramic Insulator, 35kv Pin Post Porcelain Insulator, Welcome you to join us together to make your business easier. We are always your best partner when you want to have your own business.
OEM Customized U70b Glass Insulator - High Voltage 70kn Disc Suspension Toughened Glass Insulator U70BL – Johnson Detail:

Product Design Drawings

High Voltage 70kn Disc Suspension Toughened Glass Insulator U70BL (9)

Product Technical Parameters

IEC designation U70B/146 U70B/127
Diameter D mm 255 255
Height H mm 146 127
Creepage distance L mm 320 320
Socket coupling mm 16 16
Mechanical failing load kn 70 70
Mechanical routine test kn 35 35
Wet power frequency withstand voltage kv 40 40
Dry lightning impulse withstand voltage kv 100 100
Impulse puncture voltage P.U 2.8 2.8
Power frequency puncture voltage kv 130 130
Radio influence voltage μv 50 50
Corona visual test kv 18/22 18/22
Power frequency electric arc voltage ka 0.12s/20kA 0.12s/20kA
Net weight per unit kg 3.6 3.5

Installation and maintenance

71a802a63024f1a9d

3 Installation

3.1 Appearance Check
The insulators shall be inspected one by one according to chapter 28 of GB/ T1001.1-2003 and this standard before installation, and the use of insulators that do not meet the above requirements shall be prohibited.

3.2 Insulator resistance measurement
Insulation resistance of porcelain insulators shall be measured one by one before installation. Insulators that do not meet the requirements of DLT626 shall not be used.

3.3 Precautions
During installation, insulators should be handled with care, not thrown, and avoid collision and friction with sharp objects.

images.rednet

4 Operation and Maintenance
4.1 document
The operating unit shall establish insulator files in accordance with DL/T 626.

4.2 maintenance
During inspection and inspection of insulators, if it is found that the lock pin is missing or the insulator has zero value, live operation or power failure repair shall be adopted, and the insulators shall be inspected in time according to the following provisions.
If one of the following conditions occurs, the insulator can be determined to be invalid. A) Cracks and yellow rust spots appear on the iron cap (acid reflux); B) Bending and cracking of steel feet; C) Severe arc burning of iron cap and steel foot;
D) iron cap, insulation and steel foot are not on the same axis: e) porcelain cracks occur;
F) Insulation parts are seriously burned by partial discharge and partial shedding occurs; G) Cracks or skew appear in the cement at the steel foot;
H) Corrosion of steel feet occurs as described in DLT626-2005.

pic.zhaoshang100

Pictures from the Internet

Packaging

jrtfj


Product detail pictures:

OEM Customized U70b Glass Insulator - High Voltage 70kn Disc Suspension Toughened Glass Insulator U70BL – Johnson detail pictures

OEM Customized U70b Glass Insulator - High Voltage 70kn Disc Suspension Toughened Glass Insulator U70BL – Johnson detail pictures

OEM Customized U70b Glass Insulator - High Voltage 70kn Disc Suspension Toughened Glass Insulator U70BL – Johnson detail pictures

OEM Customized U70b Glass Insulator - High Voltage 70kn Disc Suspension Toughened Glass Insulator U70BL – Johnson detail pictures

OEM Customized U70b Glass Insulator - High Voltage 70kn Disc Suspension Toughened Glass Insulator U70BL – Johnson detail pictures

OEM Customized U70b Glass Insulator - High Voltage 70kn Disc Suspension Toughened Glass Insulator U70BL – Johnson detail pictures

OEM Customized U70b Glass Insulator - High Voltage 70kn Disc Suspension Toughened Glass Insulator U70BL – Johnson detail pictures

OEM Customized U70b Glass Insulator - High Voltage 70kn Disc Suspension Toughened Glass Insulator U70BL – Johnson detail pictures


Related Product Guide:

We have many excellent staff members good at marketing, QC, and dealing with kinds of troublesome problem in the production process for OEM Customized U70b Glass Insulator - High Voltage 70kn Disc Suspension Toughened Glass Insulator U70BL – Johnson, The product will supply to all over the world, such as: Kuwait, Austria, Australia, Our company always provides good quality and reasonable price for our customers. In our efforts, we already have many shops in Guangzhou and our products have won praise from customers worldwide. Our mission has always been simple: To delight our customers with best quality hair products and deliver on time. Welcome new and old customers to contact us for the future long term business relationships.
  • We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Ina from Dominica - 2018.11.06 10:04
    Cooperate with you every time is very successful, very happy. Hope that we can have more cooperation!
    5 Stars By Doris from Islamabad - 2018.09.29 17:23

    Related Products