Feedback (2)

We keep on with the theory of "quality first, provider initially, constant improvement and innovation to meet the customers" with the management and "zero defect, zero complaints" as the standard objective. To great our company, we deliver the merchandise using the fantastic excellent at the reasonable price for Pin Insulator, 210kn Ceramic Insulator, Low Voltage Porcelain Insulator, Base on the business concept of Quality first, we would like to meet more and more friends in the word and we hope provide the best product and service to you.
Manufactur standard Stay Insulator - Hot dip galvanized steel Electric Power Fitting – Johnson Detail:

Products Information

1. Different applicable places

1. Nll-2 strain clamp: applicable to 10kV and below overhead lines.

2. Nld-2 strain clamp: used for corner, connection and terminal connection. Spiral aluminum clad steel wire has very strong tensile strength and no concentrated stress, which plays a role in protecting and assisting vibration reduction of optical cable.

2. Different functions

1. Nll-2 tension clamp: fix aluminum stranded wire or steel core aluminum stranded wire on the tension rod. When it is used for overhead insulated aluminum conductor, it is used together with the insulating cover for insulation protection.

2. Nld-2 tension clamp: it is used to fix the conductor or lightning wire on the tension insulator string of non-linear pole and tower for anchoring. It is also used to fix the stay wire of stay wire pole and tower.

3. Different characteristics

1. Nll-2 strain clamp: the clamp body is made of high-strength aluminum alloy, with smooth appearance, long service life, convenient installation and use and no power loss. It is an energy-saving certified product.

2. Nld-2 tension clamp: Tension pre twisted wire and supporting connecting fittings. The grip strength of the clamp shall not be less than 95% of the rated tensile strength of the optical cable, which is convenient and fast to install and reduces the construction cost. It is applicable to ADSS optical cable lines with span ≤ 100m and line angle < 25 °.”

W Series SOCKET EYE
Basic Data
Type Dimensions(mm) Coupling size Cantilever streength (kn) Weight (kg)
Φ b H A B
W-7A 20 16 70 34.5 19.2 16 70 0.80
W-7B 20 16 115 34.5 19.2 16 70 0.92
W-10 20 18 85 34.5 19.2 16 100 0.90
W-12 24 20 85 34.5 19.2 16 120 1.30
W-30 39 32 110 51.0 27.5 24 300 3.50

w-7b socket eye 2

Basic Data
Type Dimensions(mm) Coupling size Cantilever streength (kn) Weight (kg)
d Φ b H D D1
Q-7 17 18 16 50 33.3 17 16 70 0.27
QP-7 17 20 16 50 33.3 17 16 70 0.30
QP-10 17 20 16 50 33.3 17 16 100 0.32
QP-12 17 24 18 50 33.3 17 20 120 0.40
QP-12G 17 24 17 50 33.3 17 16 120 0.40
QP-16 21 26 20 60 41 21 20 160 0.50
QP-20 25 26 24 80 49 25 24 200 0.95
QP-21D 21 30 24 80 41 21 20 210 0.90
QP-30 25 39 28 80 49 25 24 300 1.05

Q7-BALL EYE 1

QH Series BALL EYE
Basic Data
Type Dimensions(mm) Coupling size Cantilever streength (kn) Weight (kg)
R b H H1 D D1
QH-7 12 16 100 57 33.3 17 16 70 0.6
QH-10 12 16 110 60 33.3 17 16 100 1.1
QH-12 11 19 90 45 33.3 17 16 120 1.1
QH-16 13 18 127 80 41.0 21 20 160 1.3
QH-21 16 20 150 80 41.0 21 20 210 1.3
QH-30 17 22 150 98 49.0 25 24 300 1.7

QH-BALL EYE 1

U Series Shackle
Basic Data
Type Dimensions(mm) Cantilever streength (kn) Weight (kg)
C M d H R
U-7 20 16 16 80 10 70 0.44
U-10 22 18 18 85 11 100 0.54
U-12 24 22 20 90 12 120 0.96
U-16 26 24 22 95 13 160 1.47
U-21 30 27 25 100 15 210 2.20
U-25 34 30 28 110 17 250 2.79
U-30 38 36 30 130 19 300 3.75

U-SHACKLE
2


Product detail pictures:

Manufactur standard Stay Insulator - Hot dip galvanized steel Electric Power Fitting – Johnson detail pictures

Manufactur standard Stay Insulator - Hot dip galvanized steel Electric Power Fitting – Johnson detail pictures

Manufactur standard Stay Insulator - Hot dip galvanized steel Electric Power Fitting – Johnson detail pictures

Manufactur standard Stay Insulator - Hot dip galvanized steel Electric Power Fitting – Johnson detail pictures

Manufactur standard Stay Insulator - Hot dip galvanized steel Electric Power Fitting – Johnson detail pictures

Manufactur standard Stay Insulator - Hot dip galvanized steel Electric Power Fitting – Johnson detail pictures

Manufactur standard Stay Insulator - Hot dip galvanized steel Electric Power Fitting – Johnson detail pictures

Manufactur standard Stay Insulator - Hot dip galvanized steel Electric Power Fitting – Johnson detail pictures

Manufactur standard Stay Insulator - Hot dip galvanized steel Electric Power Fitting – Johnson detail pictures


Related Product Guide:

We now have our own gross sales team, style and design workforce, technical crew, QC workforce and package group. We now have strict quality manage procedures for each system. Also, all of our workers are experienced in printing industry for Manufactur standard Stay Insulator - Hot dip galvanized steel Electric Power Fitting – Johnson, The product will supply to all over the world, such as: Cannes, Panama, Slovenia, Our company always concentrate on the development of the international market. We have a lot of customers in Russia , European countries, the USA, the Middle East countries and Africa countries. We always follow that quality is foundation while service is guarantee to meet all customers.
  • The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Emma from Swiss - 2017.06.29 18:55
    The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By tobin from Oslo - 2018.07.27 12:26

    Related Products