| 70kn Fxb1-15/70CT Power Line ElectricalComposite Polymer Insulator | |||||||
| Type | Rated voltage | Rated Rated mechanical load | Spacing | Dry arcing distance | Creepage distance | Power frequency wet withstand voltage | Dry lightning impulse withstand voltage |
| FXB1-15/70CT | 15kV | 70kN | 380mm | 195mm | 460mm | 65kV | 140kV |
Product defect
(1) The price of composite insulator is high.
(2) Composite insulators bear a very small radial (perpendicular to the center line) stress, therefore, the use of high voltage insulators used in tension rod is strictly prohibited to tread, or any form of radial load, otherwise it will lead to broken.
(3)When the composite insulator is in construction or normal operation, it is strictly prohibited to drop and rub hard objects. Because the umbrella part is silicone rubber, the texture is relatively tender, and it is easy to damage and destroy the sealing, resulting in the decline of insulation performance.
The product installation
Installation of composite insulator
1.1 check
Before installation of composite insulators, the insulators shall be inspected one by one according to GB/P5892. Insulators with torn sheath, damaged sheath or damaged end seal shall not be used.
1.2 Precautions for composite insulators
A) Handle with care, do not throw, and avoid collision and friction with sharp objects;
B) When lifting, the rope knot should be tied on the metal accessory, and it is forbidden to tie directly on the umbrella cover. When the rope touches the umbrella cover, it should be wrapped with soft cloth for protection
C) It is prohibited to step on the insulator umbrella cover;
D) Install the pressure equalizing device correctly, pay attention to the installation in place, do not install reverse, and carefully adjust the torus
Perpendicular to the axis of the insulator. For opening
Type 6 pressure equalizing device, note that both ends open in the same direction.
Packaging

Product detail pictures:









Related Product Guide:
Sticking to the principle of "Super Quality, Satisfactory service" ,We are striving to be a good business partner of you for factory Outlets for High Tension Polymer Insulator – 70kn Fxb1-1570CT Power Line Electrical Composite Polymer Insulator – Johnson, The product will supply to all over the world, such as: Puerto Rico, Serbia, Lahore, We only supply quality items and we believe this is the only way to keep business continue. We can supply custom service too such as Logo, custom size, or custom merchandise etc that can according to customer's requirement.
By Christopher Mabey from Hungary - 2018.08.12 12:27
The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
By Kimberley from Southampton - 2017.10.25 15:53