Hot sale 11kv High voltage P-11-Y Pin type Porcelain Insulator with pin spindle

Short Description:

11kv low voltage pin ceramic insulator pot with pin spindle can be used on transmission and distribution lines for medium and high voltage made of porcelain materials.
The P-11-Y 11KV pin insulator with spindle has excellent insulativity, it is used on high voltage overhead power line.

jackwu@johnsonelectricchina.com


Product Detail

Product Tags

Video

 Product Design Drawings

P-11-Y 11kv Pin type Porcelain Insulator for high voltage (10)

 Product Technical Parameters

Pin type porcelain insulators
type   P-11-Y
Dimensions
Diameter mm 135
Height mm 140
Total creepage distance mm 254
Protected creepage distance mm 102
Recommended pin height mm 152
Mechanical Values
Cantilever strength kn 11
Electrical Values
Type application voltage kv 11
Power frequency dry flashover voltage kv 75
Power frequency wet flashover voltage kv 50
50% impulse flashover voltage,positive kv 115
50% impulse flashover voltage,negative kv 150
Power frequency puncture voltage kv 150
Radio influence Voltage Data
Test voltage RMS to ground kv 15
Maximum RIV at 1000kHz μv 100
Packing and Shipping Data
Net weight,approximate kg 1.8

Pin Type Insulator BS (British Standard)

P-11-Y/P-15-Y/P-22-Y/P-33-Y/P-35-Y/P-44-Y/Pw-15-Y/Pw-22-Y/Pw-33-Y

Widely used on high voltage distribution lines, Having a better anti-fog performance, can easily handle and manufacture and  be mounted as necessary, vertically or horizontally.

H8e8e12968eef43a0b26a898c81a8e5ff8

 Specification

Pin type porcelain insulators
BS Class P-11-Y P-15-Y P-22-Y P-33-Y P-44-Y PW-15-Y PW-22-Y PW-33-Y
Creepage distance 240 298 432 630 864 432 673 851
Dry arcing distance 102 133 200 360 483 197 267 419
Main dimensions H mm 133 137 165 244 318 185 255 320
h mm 48 48 52.6 52.6 52.6 52.6 52.6 52.6
D mm 140 152 229 280 343 170 205 240
d mm 18.3 18.3 27.8 27.8 27.8 27.8 27.8 27.8
R1 mm 13 13 19 19 19 16 16 16
R2 mm 9.5 11 14.3 13 14.3 16 16 16
Cantilever Strength KN 11 11 11 13 13 11 11 13
Min Flashover Voltage Power frequency Dry kV 75 80 100 135 155 100 125 140
Wet kV 50 55 60 95 110 65 95 110
Critical impulse Pos kV 115 130 160 180 240 150 190 210
Neg kV 150 175 205 290 305 190 235 245
Withstand voltage One min Power Frequency Dry kV 65 70 90 110 125 90 110 125
Wet kV 40 50 55 75 100 60 90 100
Withstand volt.impulse kV 90 110 150 170 200 140 180 200
RIV Data Test volt. TO ground kV 15 15 22 30 44 22 30 44
Max RIV at 1000 KHz uV 8000 8000 12000 16000 25000 12000 16000 25000
Power Frequency Puncture Voltage kV 150 150 200 210 250 150 200 210
Approx.Weight kg 1.8 2 5 11 14 4.7 9.1 12.5
12

  • Previous:
  • Next:

  • Related Products