ANSI TR Series High Voltage Outdoor Station Post Ceramic Insulator

Short Description:

Hot sale High Voltage Outdoor Station Post Ceramic Insulator ANSI TR series
Types of tr series glazed station post ceramic insulator
TR-202/TR-205/TR-208/TR-210/TR-214/TR-216/TR-222/TR-225/TR-227/TR-231/TR-267/TR-278

jackwu@johnsonelectricchina.com

Product Detail

Product Tags

Performance

In power system, post insulator is widely used in bus and disconnector. During long-term operation, mechanical, thermal

Due to the comprehensive action of many factors such as electricity and environment, various physical and chemical changes will inevitably occur in insulator porcelain, resulting in electricity

The gas performance and mechanical strength decrease gradually with the increase of operation time.

The operation overvoltage is internal overvoltage, so the influence of tower height is not considered, while the lightning overvoltage is external overvoltage, and the tower height is considered. In addition, the overvoltage waveform of the operating overvoltage is closer to that of the power frequency voltage. Therefore, the zero value insulator will affect its discharge characteristics. Therefore, when calculating the tension insulator under the operating overvoltage, it is considered to add a certain number of zero value insulators more than the suspension string.

Product Design Drawings

TR-216

Product Technical Parameters

TR Series Ceramic Porcelain Station Post Insulator for Transmission
ANSI Class TR205 TR208 TR210 TR214 TR216
Dimensions
Diameter mm 178 178 191 203 232
Height mm 254 356 457 559 762
Creepage distance mm 394 610 940 1092 1892
Mechanical Values
Torsion Strength kn 38 44.5 53 62 71
Compression Strength kn 44.5 44.5 66.7 66.7 111
Cantilever Strength kn 8.9 8.9 8.9 8.9 6.7
Electrical Values
power frequency dry withstand voltage kv 85 110 145 170 235
power frequency wet withstand voltage kv 55 75 100 125 180
Critical impulse flashover voltage,positive kv 125 170 225 280 390
Critical impulse flashover voltage,negative kv 200 250 290 340 475
Impulse Withstand voltage kv 110 150 200 250 300
Power frequency dry flashover voltage kv 55 75 100 125 180
Power frequency wet flashover voltage kv 40 60 80 100 145
Radio influence Voltage Data
Impulse Withstand Voltage kv 110 150 200 250 350
Packing and Shipping Data
Net weight,approximate kg 7 11 16 21 30

TR-202

Good Quality High Voltage ANSI TR-202 Outdoor Station Post Ceramic Insulator 

202

 

TR-205

Hot sale 44kn High Voltage  ANSI TR-205 Outdoor Station Post Ceramic Insulator

205

 

TR-208

High quality ANSI TR-208 44kn High Voltage Outdoor Station Post Ceramic Insulator 

208

 

TR-210

66kn 34.5KV ANSI CLASS TR-210 High Voltage Outdoor Station Post Ceramic Insulator

210

 

TR-214

Hot sale High Voltage ANSI TR-214 Outdoor Station Post Ceramic Insulator

214

 

TR-216

Good Quality 111kn High Voltage Outdoor Station Post Ceramic Insulator ANSI TR-216

216

 

TR-222

Best Price ANSI CLASS TR-222 High Voltage Outdoor Station Post Ceramic Insulator

222

 

TR-225

15kv High Voltage ANSI TR-225 Outdoor Station Post Ceramic Insulator

225

 

TR-227

23kv ANSI class TR-227 High Voltage Outdoor Station Post Ceramic Insulator china Factory direct prize

227

 

TR-231

Hot sale 35KV ANSI CLASS TR-231 High Voltage Outdoor Station Post Ceramic Insulator

231

 

TR-267

46KV ANSI CLASS TR-267 High Voltage Outdoor Station Post Ceramic Insulator

267

 

TR-278

69KV ANSI CLASS TR-278 High Voltage Outdoor Station Post Ceramic Insulator

278