ANSI TR Series High Voltage Outdoor Station Post Ceramic Insulator
Performance
In power system, post insulator is widely used in bus and disconnector. During long-term operation, mechanical, thermal
Due to the comprehensive action of many factors such as electricity and environment, various physical and chemical changes will inevitably occur in insulator porcelain, resulting in electricity
The gas performance and mechanical strength decrease gradually with the increase of operation time.
The operation overvoltage is internal overvoltage, so the influence of tower height is not considered, while the lightning overvoltage is external overvoltage, and the tower height is considered. In addition, the overvoltage waveform of the operating overvoltage is closer to that of the power frequency voltage. Therefore, the zero value insulator will affect its discharge characteristics. Therefore, when calculating the tension insulator under the operating overvoltage, it is considered to add a certain number of zero value insulators more than the suspension string.
Product Design Drawings
Product Technical Parameters
TR Series Ceramic Porcelain Station Post Insulator for Transmission | ||||||
ANSI Class | TR205 | TR208 | TR210 | TR214 | TR216 | |
Dimensions | ||||||
Diameter | mm | 178 | 178 | 191 | 203 | 232 |
Height | mm | 254 | 356 | 457 | 559 | 762 |
Creepage distance | mm | 394 | 610 | 940 | 1092 | 1892 |
Mechanical Values | ||||||
Torsion Strength | kn | 38 | 44.5 | 53 | 62 | 71 |
Compression Strength | kn | 44.5 | 44.5 | 66.7 | 66.7 | 111 |
Cantilever Strength | kn | 8.9 | 8.9 | 8.9 | 8.9 | 6.7 |
Electrical Values | ||||||
power frequency dry withstand voltage | kv | 85 | 110 | 145 | 170 | 235 |
power frequency wet withstand voltage | kv | 55 | 75 | 100 | 125 | 180 |
Critical impulse flashover voltage,positive | kv | 125 | 170 | 225 | 280 | 390 |
Critical impulse flashover voltage,negative | kv | 200 | 250 | 290 | 340 | 475 |
Impulse Withstand voltage | kv | 110 | 150 | 200 | 250 | 300 |
Power frequency dry flashover voltage | kv | 55 | 75 | 100 | 125 | 180 |
Power frequency wet flashover voltage | kv | 40 | 60 | 80 | 100 | 145 |
Radio influence Voltage Data | ||||||
Impulse Withstand Voltage | kv | 110 | 150 | 200 | 250 | 350 |
Packing and Shipping Data | ||||||
Net weight,approximate | kg | 7 | 11 | 16 | 21 | 30 |
TR-202
Good Quality High Voltage ANSI TR-202 Outdoor Station Post Ceramic Insulator
TR-205
Hot sale 44kn High Voltage ANSI TR-205 Outdoor Station Post Ceramic Insulator
TR-208
High quality ANSI TR-208 44kn High Voltage Outdoor Station Post Ceramic Insulator
TR-210
66kn 34.5KV ANSI CLASS TR-210 High Voltage Outdoor Station Post Ceramic Insulator
TR-214
Hot sale High Voltage ANSI TR-214 Outdoor Station Post Ceramic Insulator
TR-216
Good Quality 111kn High Voltage Outdoor Station Post Ceramic Insulator ANSI TR-216
TR-222
Best Price ANSI CLASS TR-222 High Voltage Outdoor Station Post Ceramic Insulator
TR-225
15kv High Voltage ANSI TR-225 Outdoor Station Post Ceramic Insulator
TR-227
23kv ANSI class TR-227 High Voltage Outdoor Station Post Ceramic Insulator china Factory direct prize
TR-231
Hot sale 35KV ANSI CLASS TR-231 High Voltage Outdoor Station Post Ceramic Insulator
TR-267
46KV ANSI CLASS TR-267 High Voltage Outdoor Station Post Ceramic Insulator
TR-278
69KV ANSI CLASS TR-278 High Voltage Outdoor Station Post Ceramic Insulator